HORIBA Laqua Twin EC-Temp meter , 2-point Calibration (0 – 199 uS/cm; 200 – 1999 uS; 2.00 – 19.99 mS/cm)
£101.00 ex. VAT
Customers based outside of the UK, please contact us directly for assistance: jingle@harvestagri.co.uk or +44 7984 018400
The HORIBA Laqua Twin EC-Temp Meter Model EC-11 delivers unparalleled precision in a compact, portable design, ideal for direct electrical conductivity measurements. This advanced tool is capable of analyzing an extensive range of substances including viscous liquids, solids, and powders. With its minimal sample volume requirement—just 0.1ml or 0.05ml with the use of a sampling sheet B—the EC-11 ensures efficient use of your valuable samples. This meter offers a robust measurement range from 0 to 19.99 mS/cm, providing accuracy within ±2% of full scale for each range.
Experience precision in a compact form with the HORIBA Laqua Twin EC-Temp Meter, an innovative solution for direct electrical conductivity measurement in small samples. Its unique sensor design is versatile enough to analyze a variety of substances, from viscous liquids and solids to powders.
Simplify your laboratory work with its easy-to-use interface, requiring only a few drops of sample or standard solution on the sensor. Enjoy a broad measurement range of 2 to 9900 ppm (0.1 to 430 mmol/L), with an accuracy of ?10% of the actual value. This meter is a complete package, including 1413 ?S/cm and 12.88 mS/cm standard solutions, conditioning solution, batteries, and comprehensive manuals.
Ideal for fieldwork or lab use, it comes with a protective carrying case and operates optimally within a range of 5 to 40?C. Rely on a robust 2-year warranty for the meter and 6 months for the sensor, ensuring reliability and peace of mind. The HORIBA Laqua Twin EC-Temp Meter is a must-have for professionals seeking precise, hassle-free conductivity measurements.
EC-11
- The only pocket meter that can directly measure Electrical Conductivity in a 0.1ml sample (or 0.05ml sample with sampling sheet B).
- Unique sensor allows measurement of viscous liquids, solids, and even powder samples.
- No need for a beaker to calibrate your meter or measure a sample. Just place few drops of the standard or sample onto the flat sensor. This procedure saves you time and prevents wasting your precious sample.
- Measurement range 2 to 9900 ppm (mg/L).? ( 0.1 to 430 mmol/L. )
- Accuracy ?? 10% of actual value
- Supplied with 150 and 2000 ppm Standard solutions,? (14ml each), 5 x sampling sheet B, 2 x CR2032 batteries, dropper, instruction and quick manual
- Operating conditions: 5 to 40?C, 85% or less relative humidity
- Warranty: 2 years – meter; 6 months – sensor
- Packed in handy carrying case
- Supplied with 1413 microS/cm and 12.88 mS/cm standard solutions (14ml each),? conditioning solution (4ml),? 2 x CR2032 batteries, dropper, instruction and quick manuals
Model EC-11 Technical Specifications
Measurement Principle: Utilizes an Ion Selective Electrode for precise conductivity measurements across a variety of sample types.
Minimum Sample Volume: Requires only 0.12 ml, making it ideal for testing where sample conservation is critical.
Measurement Range: Broad spectrum range from 0 to 19.99 mS/cm, segmented into three scales: 0 to 199 µS/cm, 200 to 1999 µS/cm, and 2.00 to 19.99 mS/cm, for tailored application across diverse environments.
Resolution: Offers high resolution across concentrations: 1 ppm from 0 to 99 ppm, 10 ppm from 100 to 990 ppm, and 100 ppm from 1000 to 9900 ppm, ensuring detailed measurement at any scale.
Accuracy: Delivers reliable results with an accuracy of ±2% of full scale for each specific range, ensuring precise data collection.
Calibration Points: Supports up to 2 calibration points for enhanced accuracy and performance consistency.
Temperature Features:
- Display Range: 0 to 50.0 °C, accommodating a wide range of environmental conditions.
- Calibration Range: 5 to 40.0 °C, allowing for precise adjustments based on operational environment.
Display: Features a custom monochrome digital LCD with backlight, enhancing readability in varied lighting conditions.
Operating Conditions:
- Temperature: Operates effectively within 5 to 40.0 °C.
- Humidity: Designed to function optimally at 85% or less relative humidity, without condensation.
Power Supply: Powered by two CR2032 batteries, combining efficiency with convenience.
Battery Life: Offers approximately 400 hours of continuous use without backlight, maximizing operational longevity.
Material: Constructed from durable ABS epoxy, providing robustness for field and lab usage.
Dimensions and Weight: Compact and lightweight design, measuring 164 x 29 x 20 mm and weighing approximately 55 g (including sensor and batteries), ideal for portable applications.
Advanced Functionalities:
- Automatic Range Selection: Automatically selects the measurement range based on sample conductivity.
- Auto Standard Recognition: Streamlines calibration with automatic standard recognition.
- Temperature Compensation: Adjusts readings based on the sample temperature to maintain accuracy.
- Auto Hold / Auto Stable Measurement: Captures and holds stable readings automatically, simplifying data collection.
- Switchable Backlight: Allows visibility in low-light conditions.
- Automatic Power Off: Conserves battery by powering down after 30 minutes of inactivity.
- Low Battery Indicator: Alerts user when battery life is low to prevent unexpected power loss.
- IP67 Dust and Waterproof: Ensures durability and functionality in harsh conditions.
- Replaceable Sensor: Facilitates easy maintenance and extends the equipment’s lifespan.
The HORIBA Laqua Twin EC-Temp Meter EC-11 combines advanced technological features and durable construction, making it an indispensable tool for professionals requiring precise, reliable conductivity measurements in both laboratory and field environments.
This is an imported product and the price is dependent on the exchange rate at the time of purchase. Please contact us directly for a firm quotation.
Applications
The EC-11 is suitable for various applications, including:
- Environmental Science: Measuring soil or water salinity to assess pollution and contamination levels.
- Chemical and Material Processing: Monitoring and controlling concentrations in chemical solutions and industrial processes.
- Food and Beverage Industry: Testing water quality and other soluble substances to ensure product safety and quality.
- Academic and Research Laboratories: Essential for experiments requiring precise measurements of electrical conductivity.
Manuals/How To Use and Set Up
Setting Up Your EC-Temp Meter:
- Battery Installation: Insert the provided CR2032 batteries into the battery compartment.
- Initial Calibration:
- Apply a few drops of the 1413 µS/cm standard solution to the sensor.
- Select the calibration function and follow the prompts to adjust the meter according to this standard.
- Repeat with the 12.88 mS/cm solution for a comprehensive two-point calibration.
- Taking Measurements:
- Place a small sample directly onto the sensor or use the sampling sheet for minimal volumes.
- Read the conductivity level displayed on the digital LCD, which also provides temperature compensation and calibration.